home *** CD-ROM | disk | FTP | other *** search
- ;--------------------------------------------
- ;
- ; Sample GDSUSER.CFG
- ; Remove the leading ";" to activate a line.
- ;
- ;--------------------------------------------
- ;AUTO, /G640X480X8 ;start in this mode
- AUTO, /A2 ;Alias = max
- ;AUTO, /W1 ;Auto write arrays after first save.
- ;AUTO, /NAAA%03d ;Save file name as "AAA000" (001,002,etc)
- ;AUTO, /E1 ;Turn auto-fit to ON.
- ;AUTO, /F1000 ;only display extension
- ;AUTO, /Z300 ;3.0 second delay for slideshows
- ;AUTO, /R1 ;LOCK video mode
- ;AUTO, /!0 ;don't make annoying beeps
- ;AUTO, /T132x44 ;start up in this text mode
-
- ;AUTO, /#LPT3 ;default to LPT3:
- AUTO, /#LPT1 ;default to LPT1:
-
- ;-----------------------------------------------------------------------------
- ; SCANNER HARDWARE CONFIGURATIONS:
- ;=============================================================================
- ;OVERVIEW: ('*' means that support requires manufacturer's device driver)
- ;* /J0 Epson ES-300C one pass 24 bit color scanner
- ; /J1 Jovian VIA 16 bit image capture board (320x240)
- ;* /J2 Microtek MSF-300Z three pass 24 bit flatbed color scanner
- ;* /J3 Microtek Scanmaker three pass 24 bit 1850 slide scanner
- ;* /J4 Microtek MSF-300G 8 bit flatbed gray scale scanner
- ;* /J5 Microtek MSF-600Z three pass 24 bit flatbed color scanner
- ;* /J6 Microtek MSF-600G 8 bit flatbed gray scale scanner
- ; /J7 Jovian SVIA 16 bit image capture board (640x480)
- ;* /J8 Sharp JX-300 one pass 24 bit color scanner
- ;-----------------------------------------------------------------------------
-
-
-
- ; EPSON SETTINGS:
- ;----------------
- ;auto,/J0 ;Epson ES-300c ESC/I w/device driver loaded
- ;auto,/yr-50 /yg-127 /yb-150 /ya-70 ;gamma values for Epson ES-300c
-
-
-
- ; JOVIAN VIA/SVIA SETTINGS:
- ;-----------------------
- ;auto,/J1 /=A49152 ;Jovian VIA ICB addr=C0000 alternate 5
- ;auto,/J1 /=A50176 ;Jovian VIA ICB addr=C4000 alternate 6
- ;auto,/J1 /=A51200 ;Jovian VIA ICB addr=C8000 alternate 7
- ;auto,/J1 /=A52224 ;Jovian VIA ICB addr=CC000 primary address
- ;auto,/J1 /=A53248 ;Jovian VIA ICB addr=D0000 alternate 1
- ;auto,/J1 /=A54272 ;Jovian VIA ICB addr=D4000 alternate 2
- ;auto,/J1 /=A55296 ;Jovian VIA ICB addr=D8000 alternate 3
- ;auto,/J1 /=A56320 ;Jovian VIA ICB addr=DC000 alternate 4
-
- ;auto,/J7 /=A49152 ;Jovian SVIA ICB addr=C0000 alternate 5
- ;auto,/J7 /=A50176 ;Jovian SVIA ICB addr=C4000 alternate 6
- ;auto,/J7 /=A51200 ;Jovian SVIA ICB addr=C8000 alternate 7
- ;auto,/J7 /=A52224 ;Jovian SVIA ICB addr=CC000 primary address
- ;auto,/J7 /=A53248 ;Jovian SVIA ICB addr=D0000 alternate 1
- ;auto,/J7 /=A54272 ;Jovian SVIA ICB addr=D4000 alternate 2
- ;auto,/J7 /=A55296 ;Jovian SVIA ICB addr=D8000 alternate 3
- ;auto,/J7 /=A56320 ;Jovian SVIA ICB addr=DC000 alternate 4
-
-
-
- ; MICROTEK SETTINGS: (also XRS Transparency scanners)
- ;--------------------------------------------------------
- ;auto,/=A256 ;Microtek PCY/MCY scanner interface (base addr=0x100)
- ;auto,/=A288 ;Microtek PCY/MCY scanner interface (base addr=0x120)
- ;auto,/=A320 ;Microtek PCY/MCY scanner interface (base addr=0x140)
- ;auto,/=A352 ;Microtek PCY/MCY scanner interface (base addr=0x160)
- ;auto,/=A384 ;Microtek PCY/MCY scanner interface (base addr=0x180)
- ;auto,/=A416 ;Microtek PCY/MCY scanner interface (base addr=0x1a0)
- ;auto,/=A448 ;Microtek PCY/MCY scanner interface (base addr=0x1c0)
- ;auto,/=A480 ;Microtek PCY/MCY scanner interface (base addr=0x1e0)
- ;auto,/=A512 ;Microtek PCY/MCY scanner interface (base addr=0x200)
- auto,/=A544 ;Microtek PCY/MCY scanner interface (base addr=0x220)
- ;auto,/=A576 ;Microtek PCY/MCY scanner interface (base addr=0x240)
- ;auto,/=A608 ;Microtek PCY/MCY scanner interface (base addr=0x260)
- ;auto,/=A640 ;Microtek PCY/MCY scanner interface (base addr=0x280)
- ;auto,/=A672 ;Microtek PCY/MCY scanner interface (base addr=0x2a0)
- ;auto,/=A704 ;Microtek PCY/MCY scanner interface (base addr=0x2c0)
- ;auto,/=A736 ;Microtek PCY/MCY scanner interface (base addr=0x2e0)
- ;auto,/=A768 ;Microtek PCY/MCY scanner interface (base addr=0x300)
- ;auto,/=A800 ;Microtek PCY/MCY scanner interface (base addr=0x320)
- ;auto,/=A832 ;Microtek PCY/MCY scanner interface (base addr=0x340)
- ;auto,/=A864 ;Microtek PCY/MCY scanner interface (base addr=0x360)
- ;auto,/=A896 ;Microtek PCY/MCY scanner interface (base addr=0x380)
- ;auto,/=A928 ;Microtek PCY/MCY scanner interface (base addr=0x3a0)
- ;auto,/=A960 ;Microtek PCY/MCY scanner interface (base addr=0x3c0)
- ;auto,/=A992 ;Microtek PCY/MCY scanner interface (base addr=0x3e0)
-
- ;auto,/J2 ;Microtek color/gray scale scanner (MSF-300Z)
- ;auto,/J3 ;Microtek Scanmaker 1850 (color slide scanner)
- ;auto,/J4 ;Microtek gray scale scanner (MSF-300G)
- ;auto,/J5 ;Microtek color/gray scale scanner (MSF-600Z)
- ;auto,/J6 ;Microtek color/gray scale scanner (MSF-600G)
-
- ;auto,/yr110 /yg75 /yb12 /ya76 ;gamma values for Microtek Scanners
-
-
- ; DEFAULT COLOR/SHARPENING LEVELS:
- ;------------------------------------
- auto,/=r0 ;default red level
- auto,/=g0 ;default green level
- auto,/=b0 ;default blue level
- auto,/=c0 ;default contrast level
- auto,/=+0 ;default brightness level
- auto,/=l0 ;default color level
- auto,/=s4 ;default sharpening level
-
-
-